Search
   Search
Domestic Products
P.T.L Semi-Automatic
P.T.F Washable Filter
P.T.H Water Improver
Industrial Applications
What's New
Technical Specification  >>  P.T.H Controlled Efficiency Test

P.T.H Controlled Efficiency Test

Abstract
A group of five boilers, 30 liter electrical water heaters were operated against a group pf five boilers connected to five "P.T.H" Water Improver units. All boilers were operated simultaneously under the same conditions.

Program of boilers operation
Operation of the whole system was conducted and controlled automatically by a programmer. At a water temperature in the boiler of 60°C, emptying and filling taps are opened for 4 minutes, during which the heating stops and the boilers cool.
Water flow to boilers was set up to 10L\min.
*Heating elements (1500w, 10.6 w\cm).
Total hardness: 140 mg/l.

Results
Table 1 summarizes the results of the system operation during 650 hours.


Results summary

"P.T.H"
Treated boilers

Controls

Water consumption (liters)

52,625

54,933

Electricity consumption (kw)

908.5

1022.64

Kw\m³ Water

17.26

18.62

Scale weight (gram)

19.5 - 80.8

184.4 - 353.5

Efficiency range (%)

72 - 92

Electricity Range (%) = (M2-M1)/ M2 x 100

M1= Scale and precipitate dry weight of the P.T.H treated boiler.

M2= Scale and precipitate dry weight of the control boiler.


Scale formation during 650 hours of operation:

A 1 mm crust of lime scale on a heating element is equal to a 10% increase in energy consumption.

CONCLUSION

P.T.H" Water Improver reduces scale formation in boilers with an efficiency range of 72% - 92% and electricity saving of 5% - 20%.


With P.T.H Without P.T.H

Signed by cdtech - Web Development and Design  
  Home | Site Map | Contact Us